Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
2.
Rev Med Chil ; 141(1): 7-14, 2013 Jan.
Artigo em Espanhol | MEDLINE | ID: mdl-23732408

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is taking a leading role in the management of patients with severe aortic stenosis. Valve replacement surgery prolongs survival and is the technique of choice considering its historical background and long experience worldwide. Recently however, TAVI has positioned itself as the only standard therapy for symptomatic patients who are not candidates for surgery. AIM: To report the experience with this new technique comparing our results with those reported in the literature. MATERIAL AND METHODS: Between May 2010 and December 2011,17 patients aged 81 ± 7.3 years (58.8% men with an Euro SCORE 29 ± 22.4%) underwent a TAVI. RESULTS: The median transvalvular gradient was 54 ± 15.7 mmHg. All patients received a CoreValve™. Technical success was 100%, with a post implant gradient of 6.29 ± 3.3 mmHg. Residual aortic regurgitation was observed in 94%, none greater than grade II. There were no complications at the vascular access site. One patient developed cardiac tamponade during the procedure. Permanent pacemaker implantation was required in 35.2%. Hospital mortality rate was 5.8%, a figure that remained unchanged at 30 days of follow-up. CONCLUSIONS: In high-risk patients with aortic stenosis, TAVI has a high success rate and a low rate of complications. Besides an appropriate patient selection, a trained multidisciplinary team and technical conditions to solve possible complications of the procedure are required.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/normas , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/normas , Mortalidade Hospitalar , Humanos , Masculino , Resultado do Tratamento
3.
Rev. méd. Chile ; 141(1): 7-14, ene. 2013. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-674039

RESUMO

Background: Transcatheter aortic valve implantation (TAVI) is taking a leading role in the management of patients with severe aortic stenosis. Valve replacement surgery prolongs survival and is the technique of choice considering its historical background and long experience worldwide. Recently however, TAVI has positioned itself as the only standard therapy for symptomatic patients who are not candidates for surgery. Aim: To report the experience with this new technique comparing our results with those reported in the literature. Material and Methods: Between May 2010 and December 2011,17patients aged 81 ± 7.3 years (58.8% men with an Euro SCORE 29 ± 22.4%) underwent a TAVI. Results: The median transvalvular gradient was 54 ± 15.7 mmHg. All patients received a CoreValveTM. Technical success was 100%, with a post implant gradient of 6.29 ± 3.3 mmHg. Residual aortic regurgita-tion was observed in 94%, none greater than grade II. There were no complications at the vascular access site. One patient developed cardiac tamponade during the procedure. Permanent pacemaker implantation was required in 35.2%. Hospital mortality rate was 5.8%, a figure that remained unchanged at 30 days offollow-up. Conclusions: In high-risk patients with aortic stenosis, TAVI has a high success rate and a low rate of complications. Besides an appropriate patient selection, a trained multidisciplinary team and technical conditions to solve possible complications of the procedure are required.


Assuntos
Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/normas , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/normas , Mortalidade Hospitalar , Resultado do Tratamento
4.
Rev Med Chil ; 137(10): 1363-6, 2009 Oct.
Artigo em Espanhol | MEDLINE | ID: mdl-20011945

RESUMO

Devices such as Novalung can be used as a bridge to lung transplantation while waiting for a suitable donor. We report a 50 year-old male with a terminal pulmonary fibrosis and candidate for lung transplantation. He was admitted to the hospital due to a severe deterioration of his respiratory condition, with the presence of severe respiratory acidosis despite conventional invasive respiratory support. Respiratory support with Novalung was started, resulting in a progressive reduction of pCO2 that became normal ten hours after the installation of the device. Five days later a successful lung transplantation was performed.


Assuntos
Acidose Respiratória/terapia , Oxigenação por Membrana Extracorpórea/instrumentação , Transplante de Pulmão , Cuidados Pré-Operatórios/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Listas de Espera
5.
Rev. méd. Chile ; 137(10): 1363-1366, oct. 2009. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-534045

RESUMO

Devices such as Novalung® can be used as a bridge to lung transplantation while waiting for a suitable donor. We report a 50 year-old male with a terminal pulmonary fibrosis and candidate for lung transplantation. He was admitted to the hospital due to a severe deterioration of his respiratory condition, with the presence of severe respiratory acidosis despite conventional invasive respiratory support. Respiratory support with Novalung® was started, resulting in a progressive reduction ofpCOz that became normal ten hours after the installation of the device. Five days later a successful lung transplantation wasperformed.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Acidose Respiratória/terapia , Oxigenação por Membrana Extracorpórea/instrumentação , Transplante de Pulmão , Cuidados Pré-Operatórios/instrumentação , Listas de Espera
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...